The chemical dictionary tells you the classification of pipettes and their working principle. You may feel very unfamiliar when it comes to pipettes. Pipettes are the most commonly used small containers in biological experiments. They are used for the quantitative transfer of liquids. Used in the fields of biology and chemistry.
Classification of pipettes
Pipettes (micropipettes) first appeared in 1956 and were invented by Schnitger, a scientist at the German Institute of Physiology and Chemistry. Then, in 1958, the German Eppendorf Company began to produce push-button micropipettes, becoming the first in the world. The company that produces micropipettes. The liquid suction range of these micropipettes is between 1-1000-1, which is suitable for clinical routine chemical laboratory use. The micropipette has developed to this day, not only is it more accurate, but also has a variety of varieties, such as micro distributors, multi-channel micropipettes, etc. The physical principles of sample addition are as follows: ①Use air Pad (also known as piston stroke) for sample application; ②Sampling with a positive displacement of the piston without air cushion.
Air cushion sampler
The piston stroke (air cushion) sampler can be conveniently used for sample addition of a fixed or adjustable volume liquid, and the sample volume range is less than 1ul to 10ml. The function of the air cushion in the sampler is to separate the liquid sample sucked in the plastic tip from the piston in the sampler. The air cushion moves by the spring-like movement of the piston of the sampler to drive the tip The increase in liquid, dead volume, and height in the pipette tip determines the degree of expansion of this air cushion during sample application. Therefore, the volume of the piston movement must be about 2% to 4% larger than the volume expected to be sucked. The influence of temperature, air pressure, and air humidity must be reduced by structural improvements to the air cushion sampler, so that under normal conditions Will not affect the accuracy of sample addition. The disposable tip is an important part of the sample addition system, and its shape, material properties, and degree of consistency with the sampler have a great influence on the accuracy of sample addition.
The piston is moving sampler
The sampler and distributor based on the principle of positive piston movement are affected by physical factors different from the air cushion sampler. Therefore, when the air cushion sampler is difficult to apply, the piston positive movement sampler can be used. Such as liquids with high vapor pressure, high viscosity, and a density greater than 2.0g/cm3; another example is in clinical polymerase chain reaction (PCR) determination, in order to prevent the generation of aerosol, it is best to use a positive piston moving sampler. The tip of the piston moving sampler is different from the tip of the air cushion sampler. It contains a piston that can be coupled with the piston of the sampler. This kind of tip is generally produced by the piston that is moving the sampler. Manufacturers supporting production, can not use the usual tips or tips from different manufacturers.
How the pipette works
The working principle of the pipette is that the piston achieves liquid suction and discharge through the telescopic movement of the spring. Under the push of the piston, part of the air is expelled, and the liquid is sucked in by atmospheric pressure, and then the air is pushed out by the piston to expel the liquid. Therefore, when the pipette is used, it is operated with the expansion and contraction characteristics of the spring, and the speed and strength of the pipetting can be well controlled.