Many people who use pipettes for the first time think that pipettes are easy to operate, but they are not.
Many people who use pipettes for the first time think that pipettes are easy to operate, but they are not. Pipette operation is the first step of a scientific experiment and is a very basic experimental operation, but most people have prejudices about pipette operation. In fact, the operation of the pipette is a lot of knowledge. Ask yourself a few questions to see if your operation is biased.
1. Has liquid been sucked back into the piston during operation?
2. Are you careful to ensure that there is no liquid on the outside of the nozzle when pipetting?
3. After using the pipette, have you adjusted the pipette range to the maximum value?
4. Do you place the pipette flat on the table after using it?
5. Does the pipette operate in the same way when moving viscous liquid and normal liquid?
6. How many kinds of pipettes are there?
Notes for use and maintenance of pipette:
(1) Set capacity
Set the required capacity should be adjusted to greater than the set capacity value of 1/4 turn, and then adjusted to the set value, so that the mechanical clearance can be excluded, so that the set value is accurate, that is, the first capacity adjustment button rotation more than the target capacity value of 1/4 turn, and then down to the set value.
(2) Suction operation
1. Connect proper suction nozzle;
2. Press the control button to the first gear;
3. Put the pipette nozzle vertically into the liquid level 1-6mm (depending on the pipette capacity);
The pipette with a capacity of 0.1-10ul enters 1-2mm below the liquid level
A pipette with a capacity of 2-200ul enters 2-3mm below the liquid level
A pipette with a capacity of 1-5ml enters 3-6mm below the liquid level
Note: In order to make the measurement accuracy, the suction nozzle can be pre-washed 3 times, that is, repeatedly suction and discharge liquid 3 times.
4. Make the control button slowly slide back to the original position; -- -!!!!!!
5. Wait 1-3 seconds before the pipette is removed;
Pause for 1 second below 1000UL
Pause 5-10ml for 2-3 seconds.
6. Slowly remove the nozzle and ensure that there is no liquid on the outer wall of the nozzle.
(3) Operation of draining liquid
1. The suction nozzle against the inner wall of the capacity at a certain Angle;
2. Slowly press the control button to the first gear and wait for about 1-3 seconds;
3. When the control button is pressed to the second gear, the suction nozzle will drain the remaining liquid;
4. Slow down the control button;
5. Press the ejection button to eject the nozzle.
(4) maintenance
1. If the liquid enters the piston chamber accidentally, the pollutants should be removed in time;
2. After using the pipette, set the pipette range to the maximum value, and place the pipette vertically on the pipette rack;
3. According to the frequency of use, all pipettors should be cleaned with soapy water or disinfected with 60% isopropyl alcohol regularly, then cleaned with double steam water and dried;
4. Avoid placing it at a higher temperature to prevent leakage or misalignment caused by deformation;
5. Find professionals to deal with problems in time.
(5) Precautions
1. Do not place the pipette horizontally or upside down when there is liquid in the pipette nozzle, in case the liquid flows into the piston chamber and corrodes the pipette piston;
2. Use pipette correctly. Drainage to achieve high precision. Pay special attention to the 2). 3) operation of drainage;
3. Check whether there is leakage at ordinary times: stop in the liquid for 1-3 seconds after suction to observe whether the liquid level in the suction head drops; If the liquid level drops, first check whether there is a problem with the nozzle. If there is a problem with the nozzle, replace the nozzle. If the liquid level still drops after the replacement, the piston component has a problem.
4. Pipettes that need high-temperature disinfection should first check whether the pipette used is suitable for high-temperature disinfection before processing.