Home / Products / Pipette Tip / Details
Dual Filter Tips

Dual Filter Tips

Dual filter tips, also known as barrier tips or aerosol-resistant tips, are pipette tips that have two filters built into them. These filters provide an additional layer of protection against aerosols, preventing contamination and reducing the risk of cross-contamination between samples.

Product Introduction

Dual filter tips, also known as barrier tips or aerosol-resistant tips, are pipette tips that have two filters built into them. These filters provide an additional layer of protection against aerosols, preventing contamination and reducing the risk of cross-contamination between samples.The first filter in a dual filter tip is typically located at the top of the tip, close to the pipette shaft. This filter serves to protect the pipette from liquid and aerosol contaminants that may enter the tip during pipetting. The second filter is located at the tip end of the pipette tip and serves to prevent liquid and aerosols from exiting the tip.The benefits of dual filter tips include increased sample integrity, reduced risk of contamination, and improved accuracy and precision of pipetting. These tips are particularly useful when working with hazardous or infectious samples, as they prevent the spread of aerosols and protect the user from exposure to potentially harmful substances.

 

Dual filter tips are available in a variety of sizes and can be used with most common pipettes. They are typically made from medical-grade polypropylene or other high-quality materials that are resistant to chemicals and temperature changes.When selecting dual filter tips, it is important to choose tips that are compatible with the specific pipette being used. It is also important to ensure that the filters do not affect the accuracy or precision of the pipette. To ensure optimal performance, dual filter tips should be stored in a clean, dry environment and used according to the manufacturer's instructions.In summary, dual filter tips are an essential tool for laboratories working with hazardous or infectious samples. They provide an additional layer of protection against contamination and improve the accuracy and precision of pipetting. With their many benefits, dual filter tips are a valuable addition to any laboratory's toolkit.

Part number

Volume

Color

Filter

Sterile

Packing

C30A0061-A1

50μL

Natural

No

No

96pcs/pk,24pks/cs

C30A0061-A2

50μL

Natural

Yes

No

96pcs/pk,24pks/cs

C30A0061-A3

50μL

Natural

No

Yes

96pcs/pk,24pks/cs

C30A0061-A4

50μL

Natural

Yes

Yes

96pcs/pk,24pks/cs

C30A0034-B1

50μL

Black

No

No

96pcs/pk,24pks/cs

C30A0034-B2

50μL

Black

Yes

No

96pcs/pk,24pks/cs

C30A0034-B3

50μL

Black

No

Yes

96pcs/pk,24pks/cs

C30A0034-B4

50pL

Black

Yes

Yes

96pcs/pk,24pks/cs

C30A0031-A1

200μL

Natural

No

No

96pcs/pk,24pks/cs

C30A0031-A2

200pL

Natural

Yes

No

96pcs/pk,24pks/cs

C30A0031-A3

200μL

Natural

No

Yes

96pcs/pk,24pks/cs

C30A0031-A4

200μL

Natural

Yes

Yes

96pcs/pk,24pks/cs

C30A0030-B1

200μL

Black

No

No

96pcs/pk,24pks/cs

C30A0030-B2

200μL

Black

Yes

No

96pcs/pk,24pks/cs

C30A0030-B3

200μL

Black

No

Yes

96pcs/pk,24pks/cs

C30A0030-B4

200μL

Black

Yes

Yes

96pcs/pk,24pks/cs

C30A0026-A1

1000μL

Natural

No

No

96pcs/pk,24pks/cs

C30A0026-A2

1000μL

Natural

Yes

No

96pcs/pk,24pks/cs

C30A0026-A3

1000μL

Natural

No

Yes

96pcs/pk,24pks/cs

C30A0026-A4

1000μL

Natural

Yes

Yes

96pcs/pk,24pks/cs

C30A0014-B1

1000μL

Black

No

No

96pcs/pk,24pks/cs

C30A0014-B2

1000μL

Black

Yes

No

96pcs/pk,24pks/cs

C30A0014-B3

1000μL

Black

No

Yes

96pcs/pk,24pks/cs

C30A0014-B4

1000μL

Black

Yes

Yes

96pcs/pk,24pks/cs

 

Pipette tip

  • No bending,high transparency
  • No silanization,DANse/RANse free,PCR free, No pyrogen pollution
  • Can resist high temperature(121 ℃)for 30 minutes
Pipette tip

Automatic Pipette tip

  • Black conductive tips and transparent non-conductive tips
  • The smooth inner surface reduces residues and will not waste reagent
Automatic Pipette tip

Product Features

  • The filter can prevent aerosols to enter the pipettor cavity. So it is suitable for automatic workstations.

    Product Features
  • The elongated tip is specially designed for micro suck

    Product Features
  • Low retention tube effectively reduces reagent loss

    Product Features
  • Stacked boxes save space and are easy to use

    Product Features

Product Parameter

We supply full series tips which can meet different experimental needs:
Bag/boxed,with/without filter,sterilized/unsterilized,low retention/normal

1(1).jpg

With filter

2.jpg

Non-filter type

The size of pipette tip

The size of pipette tip

Filter tip capacity:

10μL/10μL Lextra long/20μL/50μL/100μL/200μL/300μL/1000μL/1250μL

Packing

  • boxed

    Boxed

  • Stacked box

    Stacked box

  • Bagged

     

image003
low profile pcr tubes

 

 

Why must the pipette be rinsed with the solution that is to be diluted and not water?

The pipette should be rinsed with the solution that is to be diluted rather than water for several reasons:

Accuracy: Rinsing with the solution that is to be diluted ensures that the pipette is primed with the correct liquid, which helps to ensure accuracy in the final diluted solution.

Consistency: Rinsing with the solution that is to be diluted helps to ensure consistency between samples. If different solutions or water are used to rinse the pipette between samples, it can introduce variability and affect the accuracy and precision of the final diluted solution.

Contamination: Rinsing with the solution that is to be diluted helps to prevent contamination of the sample. Water or other solutions may contain impurities or residues that can contaminate the sample and affect the accuracy of the final result.

Chemical reactions: Some chemicals or solutions can react with water or other solutions, which can affect the accuracy and precision of the pipetting. Rinsing with the same solution that is to be diluted can prevent these reactions from occurring.

In summary, rinsing the pipette with the solution that is to be diluted is important to ensure accuracy, consistency, prevent contamination and avoid chemical reactions that may affect the final result. It is a critical step in the pipetting process and should not be overlooked.

 

 

Hot Tags: dual filter tips, China, suppliers, manufacturers, factory, custom, wholesale, for sale, Low Binding Pipet Tip, 1000 l Filter Universal Pipette Tip, Filter Pipette Tip, Aerosol Barrier Pipette Tip, Universal Pipette Tip, 200 L pipette

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag