Hamilton 1000ul tips are made of high-grade polypropylene and are designed for a variety of laboratory applications. They are precision-molded, uniform in size and shape, and have a low-binding surface. The tips are autoclavable and non-pyrogenic, and have a wide temperature range for use in any laboratory environment. They also have a large capacity, allowing for efficient pipetting of up to 1000ul of liquid.
The tips have a conical shape and are designed to fit a variety of pipettes. They feature a low-binding surface that helps reduce sample loss and contamination. The tips also have a small opening at the end that helps reduce air bubbles and improve pipetting accuracy. They are also color-coded, making them easy to recognize and differentiate between different sizes.
The tips are also highly durable and can withstand repeated use. They feature a long stem that helps prevent breakage and leakage, and a reinforced base that helps keep the tips securely in place.
Overall, Hamilton 1000ul tips are perfect for any laboratory environment, offering reliability, accuracy and durability. They are easy to use and highly reliable,
Pipette tip
- No bending,high transparency
- No silanization,DANse/RANse free,PCR free, No pyrogen pollution
- Can resist high temperature(121 ℃)for 30 minutes

Automatic Pipette tip
- Black conductive tips and transparent non-conductive tips
- The smooth inner surface reduces residues and will not waste reagent

Product Features
-
The filter can prevent aerosols to enter the pipettor cavity. So it is suitable for automatic workstations.

-
The elongated tip is specially designed for micro suck

-
Low retention tube effectively reduces reagent loss

-
Stacked boxes save space and are easy to use

Product Parameter
We supply full series tips which can meet different experimental needs:
Bag/boxed,with/without filter,sterilized/unsterilized,low retention/normal

With filter

Non-filter type

What are the common errors done when using micropipettes?
1. Not calibrating the micropipette before use;
2. Not properly adjusting the volume setting;
3. Not properly adjusting the plunger;
4. Not cleaning the micropipette after each use;
5. Not changing the tip after each use;
6. Not accounting for the meniscus of the liquid when measuring;
7. Not using the correct tip for the volume being pipetted;
8. Using a pipette with too much or too little liquid;
9. Not ensuring the tip is securely connected to the pipette;
10. Not ensuring the tip is the correct size for the volume being pipetted.
Hot Tags: hamilton 1000ul tips, China, suppliers, manufacturers, factory, custom, wholesale, for sale, Lab Pipette Tip, 200 L pipette Tip, Polypropylene Pipette Tip, 1000 l Universal Pipette Tip, Filter Pipette Tip, Transparent Pipette Tip
















