Thermo Scientific™ Pipette Tip is a precision instrument designed to accurately measure and transfer liquids. It is ideal for use in laboratories, medical clinics, and other scientific applications.
To use the pipette tip, first select the tip size that is best suited for the desired task. Place the tip on the pipette, making sure that it is firmly seated. Place the liquid to be measured into the pipette, then slowly depress the plunger to the desired volume. After the liquid has been dispensed, remove the tip from the pipette and dispose of it.
The Thermo Scientific™ Pipette Tip is made of a durable and chemically resistant plastic, making it ideal for use in a wide range of applications. It also features a patented design that prevents cross-contamination between samples. Additionally, the tip is designed to ensure precise measurements with minimal effort, making it easy to use for a variety of tasks.
Compared to other pipette tips, the Thermo Scientific™ Pipette Tip has several advantages. Its patented design prevents cross-contamination, and its durable plastic construction ensures long-lasting use. Additionally, its precision measurements make it ideal for precise applications, like laboratory experiments. Furthermore, its ergonomic design makes it comfortable to use, even for long periods of time.
|
Part number |
Volume |
Color |
Filter |
Sterile |
Packing |
|
C30A0061-A1 |
50μL |
Natural |
No |
No |
96pcs/pk,24pks/cs |
|
C30A0061-A2 |
50μL |
Natural |
Yes |
No |
96pcs/pk,24pks/cs |
|
C30A0061-A3 |
50μL |
Natural |
No |
Yes |
96pcs/pk,24pks/cs |
|
C30A0061-A4 |
50μL |
Natural |
Yes |
Yes |
96pcs/pk,24pks/cs |
|
C30A0034-B1 |
50μL |
Black |
No |
No |
96pcs/pk,24pks/cs |
|
C30A0034-B2 |
50μL |
Black |
Yes |
No |
96pcs/pk,24pks/cs |
|
C30A0034-B3 |
50μL |
Black |
No |
Yes |
96pcs/pk,24pks/cs |
|
C30A0034-B4 |
50pL |
Black |
Yes |
Yes |
96pcs/pk,24pks/cs |
|
C30A0031-A1 |
200μL |
Natural |
No |
No |
96pcs/pk,24pks/cs |
|
C30A0031-A2 |
200pL |
Natural |
Yes |
No |
96pcs/pk,24pks/cs |
|
C30A0031-A3 |
200μL |
Natural |
No |
Yes |
96pcs/pk,24pks/cs |
|
C30A0031-A4 |
200μL |
Natural |
Yes |
Yes |
96pcs/pk,24pks/cs |
|
C30A0030-B1 |
200μL |
Black |
No |
No |
96pcs/pk,24pks/cs |
|
C30A0030-B2 |
200μL |
Black |
Yes |
No |
96pcs/pk,24pks/cs |
|
C30A0030-B3 |
200μL |
Black |
No |
Yes |
96pcs/pk,24pks/cs |
|
C30A0030-B4 |
200μL |
Black |
Yes |
Yes |
96pcs/pk,24pks/cs |
|
C30A0026-A1 |
1000μL |
Natural |
No |
No |
96pcs/pk,24pks/cs |
|
C30A0026-A2 |
1000μL |
Natural |
Yes |
No |
96pcs/pk,24pks/cs |
|
C30A0026-A3 |
1000μL |
Natural |
No |
Yes |
96pcs/pk,24pks/cs |
|
C30A0026-A4 |
1000μL |
Natural |
Yes |
Yes |
96pcs/pk,24pks/cs |
|
C30A0014-B1 |
1000μL |
Black |
No |
No |
96pcs/pk,24pks/cs |
|
C30A0014-B2 |
1000μL |
Black |
Yes |
No |
96pcs/pk,24pks/cs |
|
C30A0014-B3 |
1000μL |
Black |
No |
Yes |
96pcs/pk,24pks/cs |
|
C30A0014-B4 |
1000μL |
Black |
Yes |
Yes |
96pcs/pk,24pks/cs |
Pipette tip
- No bending,high transparency
- No silanization,DANse/RANse free,PCR free, No pyrogen pollution
- Can resist high temperature(121 ℃)for 30 minutes

Automatic Pipette tip
- Black conductive tips and transparent non-conductive tips
- The smooth inner surface reduces residues and will not waste reagent

Product Features
-
The filter can prevent aerosols to enter the pipettor cavity. So it is suitable for automatic workstations.

-
The elongated tip is specially designed for micro suck

-
Low retention tube effectively reduces reagent loss

-
Stacked boxes save space and are easy to use

Product Parameter
We supply full series tips which can meet different experimental needs:
Bag/boxed,with/without filter,sterilized/unsterilized,low retention/normal

With filter

Non-filter type

The size of pipette tip
Filter tip capacity:
10μL/10μL Lextra long/20μL/50μL/100μL/200μL/300μL/1000μL/1250μL
Packing
-

Boxed
-

Stacked box
-



Why must a pipetman be held vertically when the tip is filled with liquid?
A pipetman must be held vertically when the tip is filled with liquid to ensure that the liquid does not spill out of the tip. By holding the pipetman vertically, the force of gravity can be used to control the speed at which the liquid enters the tip. Additionally, by keeping the pipetman upright, air bubbles can be easily seen and removed from the tip before the liquid is dispensed.
Why should you avoid submerging the micropipette tip too deep?
Submerging the micropipette tip too deep can cause sample to be drawn into the tip, which can interfere with accurate measurements. Additionally, if the sample is drawn too far into the tip, it can become stuck, which can cause damage to the micropipette.
Should the little liquid on the tip of the pipette be squeezed out why?
No, the little liquid on the tip of the pipette should not be squeezed out. This liquid should be left inside the pipette because it is necessary for accurate pipette measurements. Squeezing out the liquid could create an inaccurate measurement and lead to inaccurate results.
Why is my pipette leaking?
There could be several reasons why a pipette is leaking. It could be due to wear or damage to the rubber o-ring, the tip may not be inserted properly, or the plunger may be damaged. It is also possible that the pipette is not being properly calibrated. If the pipette is not calibrated correctly, it will not generate the proper vacuum necessary to accurately dispense liquid.
What is the purpose of wiping off the pipette tip before dispensing its contents?
Wiping off the pipette tip before dispensing its contents helps to prevent contamination by removing any material that may have been left on the tip from a prior use. This is especially important when working with sensitive materials such as reagents, bacteria, or cell cultures.
What should the pipette rinsed with before titrating?
The pipette should be rinsed with the solution being titrated before use.
Which stop do you push the plunger before drawing liquid into the tip of a micropipette?
The plunger should be pushed all the way down to the first stop before drawing liquid into the tip of a micropipette.
What will happen if the pipette is wet when blood is drawn into it?
If the pipette is wet when blood is drawn into it, the blood may not be able to flow properly into the pipette. The wetness of the pipette could also cause the sample to be contaminated by any bacteria or other contaminants that are present on the pipette. Additionally, the wetness of the pipette could cause the sample to mix with any residual liquid inside the pipette, resulting in an inaccurate sample.
COMPANY PROFILE
Established in 2016, Biorear is located in Jiaxing, Zhejiang Province, with an area of 16000 ㎡.
Biorear is devoted to development, manufacture, sales and service of consumables in the field of life science and clinical diagnosis. Company has 100k level cleanrooms for injection molding, automation systems for packaging, extraction, special process equipment, optical testing systems, material research ability and automatic inspection instruments developed for different products and application scenarios, which enables us to monitor and measure the quality of different products.
Hot Tags: thermo scientific™ pipette tip, China, suppliers, manufacturers, factory, custom, wholesale, for sale, 300 L Pipette Tip, Sterile Filter Tip, Plastic Universal Tip, Transparent Pipette Tip, 200 L pipette, 1000 l Filter Universal Pipette Tip
















